Sewer and stormwater re-diverted for a lift shaft, pit and pump installed, and a root-choked sewer cleared
The problem
A new lift shaft was going in at this home, right where the existing stormwater and sewer lines ran, so both had to be re-diverted to make way for it. When we cut into the sewer, the line was full of tree roots.
What we did
We re-diverted the stormwater and sewer lines around the new lift shaft and installed an inspection opening on the sewer. We ran a CCTV camera through about 20 m of damaged old earthenware sewer and jet blasted it clear of roots, which took about 5 hours. We then dug down outside, located the sewer and installed a new 150 mm junction and inspection opening, sent the camera upstream to a second blockage and jet blasted it clear. At the bottom of the lift shaft we supplied and installed a 450 x 450 pit and pump set-up with an alarm, connected to the existing stormwater outlet with a non-return valve, and concreted the pit in with blue metal around it. The old earthenware line is damaged, and we have recommended relining it.